STUDI LITERATUR TINJAUAN PENGGUNAAN GENERATOR PACKAGE SET DARURAT PADA SEBUAH KAPAL

  • Danny Faturachman Fakultas Teknologi Kelautan Universitas Darma Persada
  • Shahrin Febrian Fakultas Teknologi Kelautan Universitas Darma Persada
Keywords: BKI Regulation, Emergency Generator Package Set, LCT 415 GT

Abstract

Landing Craft Tank (LCT) is a type of attack landing craft to ship tanks on the waterfront. In general, LCT 415 Gross Tonnage (GT) ships are not ready to sail using emergency generators. According to Biro Klasoifikasi Indonesia (BKI) rules, only ships with more than 500 GT are required to have an emergency generator package. However, for the LCT 415 GT to gained higher level of safety, the ship is equipped with an emergency generator package installation. This generator is used as an electric power source which is used by the ship's compass in off condition. The purpose of this study wants to learned the electrical power requirements on the LCT 415 GT to determine the required emergency generator package specifications and provide an overview of the generator's placement on the main deck. Emergency generator packages are arranged to improve ship safety, crew and cargo. In an emergency, LCT 415 GT ships required a total power of 29,9408 kW. The basic package of emergency generator set selection is based on the total emergency power following BKI regulations as well as the generator safety engine package set when extreme weather conditions.

References

1. Alfith, 2017, Optimalisasi ATS (Automatic Transfer Switch) pada Genset (Generator Set) 2800 Watt Berbasis TDR, Seminar Nasional Peranan Ipteks Menuju Industri Masa Depan (pp. 226-232), Institut Teknologi Padang, Padang
2. American National Standard Institute, 1966, Electrical and Electronics Diagrams, The American Society of Mechanical Engineers, New York
3. Augmented, S. L, 2016, (June 26), An Introduction of Electric Motors, Retrieved from https://www.st.com/content/ccc/resource/sales_and_marketing/presentation/application_presentation/group0/23/a1/94/a3/39/cf/4c/37/introduction_to_electric_motors_pres.pdf/files/introduction_to_electric_motors_pres.pdf/jcr:content/ translations/en.introducti
4. BKI, 2019, Rules ,Biro Klasifikasi Indonesia, Jakarta
5. Bunga, P. M, 2015, Perancangan Sistem Pengendalian Beban Dari Jarak Jauh Menggunakan Smart Relay. E-Journal Teknik Elektro dan Komputer, 4(5).
6. Chen, K. W, 2004, The Electrical Engineering Handbook, ElSevier Academic Press, Chicago
7. Goh, H. H, (2017, October), Types of Circuit Breaker and its Application in Substation Protection, Indonesian Journal of Electrical Engineering and Computer Science. doi:10.1159/ijeecs.v8.i1. pp213-220
8. Hidayah, A, 2007, Perancangan Unit Instalasi Genset di PT Aichi Tex Indonesia. Politeknik Negri Bandung.
9. Mahon, L. L, 1992, Diesel Generator Handbook, Elsevier Butterwortth-Heinemann, Oxford
10. Putra, H. P, 2015, Analisa Menurunnya Perfoma Emergency Generator Terhadap Situasi Blackout Di Atas Kapal MV. SHANTI INDAH. Jurusan Teknika Program Diploma IV Politeknik Ilmu Pelayaran.
11. Sakura, A, 2017, Rancang Bangun Generator sebagai Sumber Energi Listrik Nanohidro, Fakultas Matematika dan Ilmu Pengetahuan Alam, Universitas Lampung, Bandar Lampung.
12. Sheldrake, L. A, 2003, Handbook of Electrical Engineering, Chichester, Wiley, England
13. Zulfauzi, A, 2019, Perancangan Sistem Emergency Genset Pada Kapal 1.
Published
2020-03-13